ADITADIT CONNECTSpec Intelligence
Back to search

AFTEC · Cable Glands - Ex d / Ex e (SWA Armoured) · Armoured Glands

AF-A2F-M20

AF-A2F Ex d/e Armoured Gland M20

Country of manufacture: United Arab Emirates

Normalized technical specification

This specification is the requirement baseline for the comparison below. Mandatory parameters are marked.

Thread TypeOptional
Metric
Thread SizeMandatory
M20
Cable TypeOptional
SWA Armoured
Armour TypeMandatory
SWA (Single Wire Armour)
Cable Diameter RangeMandatory
6.5 to 14 mm
MaterialOptional
Brass (Nickel Plated)
Ex ProtectionMandatory
Ex db IIC / Ex eb IIC
Gas GroupMandatory
IIC
Equipment Protection LevelOptional
GB
IP RatingMandatory
IP66
Temperature RangeOptional
-60 to 130 °C
IECEx CertificateOptional
IECEx ULD 21.0007X
ATEX CertificateOptional
ATEX ULD 21.0007X

Additional information from the supplier

Verify against the current manufacturer certificate before order.

Technically comparable products

Each parameter is assessed individually against the baseline. No percentage scores are used.

Meets RequirementTechnical DeviationDoes Not Meet Requirement

CMP Products

20 A2F

Thread TypeOptional

Metric

Required: Metric

Thread SizeMandatory

M20

Required: M20

Cable TypeOptional

SWA Armoured

Required: SWA Armoured

Armour TypeMandatory

SWA (Single Wire Armour)

Required: SWA (Single Wire Armour)

Cable Diameter RangeMandatory

6.5 to 13.9 mm

Required: 6.5 to 14.0 mm

MaterialOptional

Brass (Nickel Plated)

Required: Brass (Nickel Plated)

Ex ProtectionMandatory

Ex db IIC / Ex eb IIC

Required: Ex db IIC / Ex eb IIC

Gas GroupMandatory

IIC

Required: IIC

Equipment Protection LevelOptional

GB

Required: GB

IP RatingMandatory

IP66

Required: IP66

Temperature RangeOptional

-60 to 130 °C

Required: -60 to 130 °C

IECEx CertificateOptional

IECEx BAS 06.0031X

Required: IECEx ULD 21.0007X

ATEX CertificateOptional

ATEX BAS 06.0031X

Required: ATEX ULD 21.0007X

Hawke International

501/453/UNIV/A/M20

Thread TypeOptional

Metric

Required: Metric

Thread SizeMandatory

M20

Required: M20

Cable TypeOptional

SWA Armoured

Required: SWA Armoured

Armour TypeMandatory

SWA (Single Wire Armour)

Required: SWA (Single Wire Armour)

Cable Diameter RangeMandatory

6.1 to 14.0 mm

Required: 6.5 to 14.0 mm

MaterialOptional

Brass (Nickel Plated)

Required: Brass (Nickel Plated)

Ex ProtectionMandatory

Ex db IIC / Ex eb IIC

Required: Ex db IIC / Ex eb IIC

Gas GroupMandatory

IIC

Required: IIC

Equipment Protection LevelOptional

GB

Required: GB

IP RatingMandatory

IP66

Required: IP66

Temperature RangeOptional

-60 to 130 °C

Required: -60 to 130 °C

IECEx CertificateOptional

IECEx BAS 06.0012X

Required: IECEx ULD 21.0007X

ATEX CertificateOptional

ATEX BAS 06.0012X

Required: ATEX ULD 21.0007X

Peppers Cable Glands

A2F-M20

Thread TypeOptional

Metric

Required: Metric

Thread SizeMandatory

M20

Required: M20

Cable TypeOptional

SWA Armoured

Required: SWA Armoured

Armour TypeMandatory

SWA (Single Wire Armour)

Required: SWA (Single Wire Armour)

Cable Diameter RangeMandatory

7.0 to 13.0 mm

Required: 6.5 to 14.0 mm

MaterialOptional

Brass

Required: Brass (Nickel Plated)

Ex ProtectionMandatory

Ex db IIC / Ex eb IIC

Required: Ex db IIC / Ex eb IIC

Gas GroupMandatory

IIC

Required: IIC

Equipment Protection LevelOptional

GB

Required: GB

IP RatingMandatory

IP66

Required: IP66

Temperature RangeOptional

-20 to 100 °C

Required: -60 to 130 °C

IECEx CertificateOptional

IECEx SIR 08.0084X

Required: IECEx ULD 21.0007X

ATEX CertificateOptional

ATEX SIR 08.0084X

Required: ATEX ULD 21.0007X

Bimed Teknik

BTEX-A2F-M20

Thread TypeOptional

Metric

Required: Metric

Thread SizeMandatory

M20

Required: M20

Cable TypeOptional

SWA Armoured

Required: SWA Armoured

Armour TypeMandatory

SWA (Single Wire Armour)

Required: SWA (Single Wire Armour)

Cable Diameter RangeMandatory

6.5 to 13.0 mm

Required: 6.5 to 14.0 mm

MaterialOptional

Brass (Nickel Plated)

Required: Brass (Nickel Plated)

Ex ProtectionMandatory

Ex db IIB / Ex eb IIB

Required: Ex db IIC / Ex eb IIC

Gas GroupMandatory

IIB

Required: IIC

Equipment Protection LevelOptional

GB

Required: GB

IP RatingMandatory

IP68

Required: IP66

Temperature RangeOptional

-40 to 100 °C

Required: -60 to 130 °C

IECEx CertificateOptional

IECEx TUR 18.0004X

Required: IECEx ULD 21.0007X

ATEX CertificateOptional

ATEX TUR 18.0004X

Required: ATEX ULD 21.0007X